Periodically ask a qualified technician to check the following:
- the flexible rubber pipe doesn't show cracks, cuts, marks of burnings
on its full lenght;
- the material is not hardened, but shows its normal elasticity;
- the fixing clamps are not rusted;
- expiry term is not due.
If one or more abnormalities are noticed, do not attempt torepair the
pipe, but ask a technician to replace it.
IMPORTANT
Once installation has been carried complete, check the perfect seal
of every pipe fitting, using a soapy solution. NEVER USE A FLAME!
To adapt the appliance to a different gas suplly, carry out the
following instructions.
Gas Connection
LPG : use the rubber pipe
holder «B».
Natural gas : use the pipe
fitting «A».
Always insert the gasket «C»
between the pipe holder and
the connection pipe.
Adaptation to different types of gas