11.
Possibilities for insertion
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
Kitchen unit with door or drawer
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and the
oven must be installed separately for safety
reasons and to let easy remove oven from the
unit.
Technical data
Hob dimensions
Width 744 mm
Depth 510 mm
Bypass diameters
BURNER Ø BYPASS 1/100 mm
Triple Crown 56
Rapid 42
Semi-rapid 32
Auxiliary 28
Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 12 kW
Gas replacement: G30 (3+) 28-30 mbar = 858 g/h
G31 (3+) 37 mbar = 843 g/h
www.zanussi.com 15