A) supplied seal
B) supplied brackets
CAUTION!
Install the appliance only on
a worktop with flat surface.
8.8 Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
Kitchen unit with door
A) Removable panel
B) Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9. TECHNICAL INFORMATION
9.1 Hob dimensions
Width 896 mm
Depth 516 mm
9.2 Other technical data
TOTAL POWER:
Gas original:
G20/G25 (2E+) 20/25 mbar (BE) = 10,5 kW
G20 (2E) 20 mbar (LU) = 10,5 kW
Gas replacement: G30 (3+) 28-30 mbar = 763 g/h
G31 (3+) 37 mbar = 750 g/h
Electric supply: 230 V ~ 50 Hz
Appliance category: II2E+3+ (BE)
I2E (LU)
Gas connection: R 1/2"
Appliance class: 3
9.3 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Triple Crown 56
Semi-rapid 32
Auxiliary 28
ENGLISH 15