AEG IKE84443IB Instrukcja Użytkownika Strona 19

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 18
CAUTION!
Do not connect the cable
without cable end sleeve.
Two-phase connection
1. Remove the cable end sleeve from
black and brown wires.
2. Remove an insulation of the brown
and black cable ends.
3. Apply a new wire end sleeve of 1.5
mm² on each cable end. (special tool
required).
Cable cross section
N
L1
N
L
230V~ 400V 2~N
L2
One-phase connection - 230 V~ Two-phase connection - 400 V 2 ~ N
Green - yellow Green - yellow
N Blue and blue Blue and blue N
L Black and brown Black L1
Brown L2
8.4 Assembly
min.
50mm
min.
500mm
774
+1
mm
514
+1
mm
490
+1
mm
min. 55mm
750
+1
mm
R10mm
R5mm
12mm
7mm
ENGLISH 19
Przeglądanie stron 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24

Komentarze do niniejszej Instrukcji

Brak uwag