8.3 Connection cable
The hob is supplied with a connection
cable.
To replace the damaged mains cable
use the following (or higher) mains
cable type: H05V2V2-F T min 90°C.
Speak to your local Service Centre.
8.4 Electrical connection
Install the hob with a socket supply line.
If there is no socket supply line, the fixed
home electrical system must include an
isolating device with at least a 3 mm-
contact separation to enable a
simultaneous and all-pole cut off from
the mains (according to NIN SEV 1000).
8.5 Assembly
R 5mm
min.
55mm
560
+1
mm
490
+1
mm
min.
28 mm
min.
12 mm
min.
20 mm
www.aeg.com10