Wall unit mounting - Fig. 6
Mark the wall with a centre line, this will aid mounting procedure ,
position the template so that the mid line printed on the template
matches with the centre line previously drawn (1), drill two holes Ø
8mm (2).
Fit two wall plugs with hooks (3).
Hang the hood and adjust its position (4).
Remove the grease filters (5) and from the inside of the hood mark 4
points for fixing (6). Remove the hood and drill 4 holes Ø 8mm.
Fit two wall plugs (7).
Fit the chimney support (8) with wall plugs and screws close to the
ceiling, check that the support is perfectly centered.
Hang the hood again and fix securely with 4 screws (9) .
Connect a tube to the exit hole of the hood (10) long enough to reach
the outside (suction version) or the deflector connection ring (filtering
version).
Make electrical connection (11).
Fix the chimney up (12a) to the chimney support (12b).
slide the lower section of the chimney down into the housing on top
of the hood (13).