Install correctly to give shock protection.
Loose and incorrect plug and socket connections can make the terminal become too hot.
A qualified electrician must install the connections in the clamps correctly.
Use a strain relief clamp on cable.
Use the correct mains cable of type H05BB-F Tmax 90°C (or higher) for a single phase or
two phase connection.
Replace the damaged mains cable with a special cable (type H05BB-F Tmax 90°C; or
higher). Speak to your local Service Centre.
The appliance must have the electrical installation which lets you disconnect the appliance
from the mains at all poles with a contact opening width of minimum 3 mm.
You must have correct devices to isolate: line protecting cut-outs, fuses (screw type fuses
removed from the holder), earth leakage trips and contactors.
Assembly
min.
50mm
min.
50mm
min.
500mm
=
=
490
+1
mm
560
+1
mm
600mm
R 5mm
min.
25 mm
min.
20 mm
min.
28 mm
Installation instructions