9. TECHNICAL INFORMATION
9.1 Hob dimensions
Width 595 mm
Depth 525 mm
9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Triple Crown 56
Semi-rapid 32
Auxiliary 28
9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 9 kW
Gas replacement: G30 (3+) 28-30 mbar = 654 g/h
G31 (3+) 37 mbar = 643 g/h
Electric supply: 220-240 V ~ 50/60 Hz
Appliance category: II2H3+
Gas connection: G 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 4,0 1,4 146
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
www.aeg.com14